I have set the following global timing derate values:
pt_shell>set_timing_derate -late 1.05
pt_shell>set_timing_derate -early 0.95
Now, I want to reset the timing derate values on a specific instance, for example, U1;
pt_shell> reset_timing_derate [get_cells U1]
why is this command not resetting the timing derate values on the instance?
Answer:
The following cmds set the timing derate values globally on the entire current design:
pt_shell>set_timing_derate -late 1.05
pt_shell>set_timing_derate -early 0.95
pt_shell> report_timing_derate
----------Clock----------- -----------Data-----------------
Rise Fall Rise Fall
Early Late Early Late Early Late Early Late
---------------------------------------------------------------------------------------------------------------------------------------------------
Design: test
Net delay static 0.95 1.05 0.95 1.05 0.95 1.05 0.95 1.05
Net delay dynamic 0.95 1.05 0.95 1.05 0.95 1.05 0.95 1.05
Cell Delay 0.95 1.05 0.95 1.05 0.95 1.05 0.95 1.05
Cell Check --- --- --- --- --- --- --- ---
Resetting derate values on instance U1 of the design only resets the timing derate values specifically set earlier on instance U1 but does not override the global timing derate settings:
pt_shell> set_timing_derate 1.55 -cell_delay -late [get_cells U1]
pt_shell> set_timing_derate 0.55
pt_shell> report_timing_derate [get_cells U1]
---------clock------------ ------------Data------------
Rise Fall Rise Fall
Early Late Early Late Early Late Early Late
-------------------------------------------------------------------------------------------------------------------------------
Cell(leaf):U1 0.55 1.55 0.55 1.55 0.55 1.55 0.55 1.55
Cell delay
2. Reset all timing derate values set globally on the complete current design:
pt_shell> reset_timing_derate
pt_shell>report_timing_derate [get_cells U1]
-------clock-------- --------Data-------
Rise Fall Rise Fall
Early Late Early Late Early Late Early Late
---------------------------------------------------------------------------------------------------------------------
Cell(leaf):U1 --- --- --- --- --- --- --- ---
Cell delay
In conclusion, the reset_timing_derate cmd only resets the timing derate values at or below the scope where they were set. The cmd does not override the timing derate values set at a higher scope.